Single-unit orders welcomeOEM / ODMSpa, sauna and outdoor projects

Service parts · 05

Ozone, UV and Salt System Parts

Water treatment is consumables pretending to be equipment. Lamps, cells and generator chips have a service life, and the part that fails is almost always the part that wears.

UV lamp assembly, salt-chlorine cell with titanium plates and ozone module on a wet concrete bench

Cartridge, lamp or salt cell.

Consumables first, because that is what a service company reorders.

UV lamp end cap with octagonal nut and O-ring beside the salt cell viewing window

Ozone generator

Chip or corona-style generator module for spa water, supplied with the injector, the check valve and the tubing that keep water out of it.

Ozone generator in a cabinet feeding a venturi injector on the return line through a check valve

Ozone consumables

Replacement chip, fuse, tubing and the check valve that fails before the generator does.

Venturi injector inline on a braided hose with tubing looped high to an ozone check valve inside a spa cabinet

UV lamp and quartz sleeve

Lamp, quartz sleeve and the O-ring that seals it, matched on length, wattage and base.

UV lamp withdrawn from its quartz sleeve with the gland nut and O-ring beside it

UV ballast

Ballast that drives the lamp, quoted with the lamp because the pair is usually replaced together.

Sealed black UV ballast box with two cable glands beside a stainless UV chamber in a spa equipment bay

Salt cell electrode

Electrode cell for salt-chlorine systems, matched on cell type, length and housing.

Cell housing and fittings

Housing, unions and the seals around the cell.

Reference data

Lamp, cell and sleeve.

Lamps and cells are matched on dimensions and on the housing they sit in. Output figures printed by the maker are the reference; we do not restate them as our own.

Specification fields
FieldTypical options and what we confirm
Ozone outputTreatment capacity of the generator (As declared by the maker; confirmed per enquiry)
Lamp length and baseTypical: 950 mm lamp length. Base and sleeve seating confirmed per enquiry. Lamp length and wattage are quoted as a pair; a longer lamp is used at the higher ratings.
Lamp wattageQuoted range: 80 – 400 W across the UV range. The ballast match is confirmed per enquiry.
Quartz sleeve sizeSleeve outside diameter and length, measured on the old sleeve; the O-ring seat decides the seal.
Ballast typePhotograph the ballast label; the start type is read from it rather than assumed.
Cell type and lengthOptions: titanium plate cell, 2 – 25 g/h chlorine output.
Voltage and frequencyTypical: AC 100–240 V, 50/60 Hz.
Service lifeRated hours declared by the maker (As declared; confirmed per enquiry)
Cross-reference
Reference systemWhy it helps
Generator or lamp labelModel, output and voltage as printed
Housing photoSleeve diameter and seal arrangement
Old lampLength and base, measured
Spa brand and modelNarrows the treatment fitted at build
Water volumeSizes ozone and cell capacity

Consumable service life is quoted as declared by the maker rather than as a promise of ours. Brand names are used for cross-reference only.

What to read on the old unit.

These parts fail on dimensions more than on brand, so a rule in the photo saves a round trip.

  • Photo of the old lamp, cell or generator label
  • Length and diameter measured against a rule
  • Voltage and frequency at the installation
  • Water volume of the spa or swim spa
  • Whether the housing is being replaced as well
  • Destination market, since electrical approval follows it

What we do not copy.

Generators and cells are supplied as service parts. We do not copy a competitor’s control board or a complete sanitising unit built around proprietary firmware.

Consumables and housings

Lamp, sleeve, ballast, cell, generator module and the fittings around them.

No firmware copies

Units whose behaviour is defined by locked firmware are not reverse-engineered.

Documents per order

Electrical approval follows the destination market and ships with the goods.

Related reading: lamp, cell and generator parts.

Questions about water treatment parts.

How often does a UV lamp need replacing?

The maker declares a rated life in hours; the practical answer is usually once a year in a domestic spa.

Can I replace the lamp without the ballast?

Yes, if the ballast is sound. The two are often changed together because a failing ballast shortens lamp life.

Are ozone generators repairable?

The chip and the check valve are replaceable; a cracked corona cell is not.

Do salt cells come in different lengths?

Yes, and the housing they sit in decides which length is offered.

Can you match a cell without a model number?

With the cell length, the thread at each end and the housing photo, usually yes.

Which approvals apply?

Tell us the destination market; the approval route is confirmed with the documents that ship with the order.

Parts that keep treatment running.

Water treatment rarely travels alone.

Send the unit detail for a checked reply.

One enquiry covers the treatment part, the fittings it needs and the market it ships to. Replies come from the person who checks the specification, not an autoresponder.